TM 10-3930-660-10
0017 00-3
PRIMARY AND SECONDARY AIR FILTER MAINTENANCE - CONTINUED 0017 00
SERVICE - CONTINUED
CAUTION
Do not tap the element against a hard surface as this damages the element.
5. Remove loose dust by tapping element with palm of your hand. DO NOT use a hard surface.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components. DO NOT
direct compressed air against human skin. Failure to follow this warning may result in injury or death. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user must wear
protective goggles or face shield.
6. To remove remaining dust, use compressed air under
30 psi (207 kPa). Blow the air up and down the pleats
from the inside of the element. Be careful not to dam-
age or tear paper element.
CAUTION
DO NOT wash element in fuel oil, oil, gasoline, or solvent. DO NOT use compressed air to remove water
from an element.
7. To clean oily or sooty element, wash thoroughly with warm water and non-foaming detergent. Rinse element with clean
water and allow element to air dry. Clean outer cover and rubber evacuator valve with soap and water.
409-067