TM 10-3930-660-10
0012 00-19
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
47 Weekly Exhaust
System
Check exhaust system for loose
or missing mounting hardware.
WARNING
Ether fuel is extremely flammable and toxic. DO NOT
smoke and make sure you are in a well-ventilated area away
from heat, open flames or sparks. Wear eye protection.
Avoid contact with skin and eyes and avoid breathing ether
fumes. If fluid enters or fumes irritate the eyes, wash imme-
diately with large quantities of clean water for 15 minutes.
Seek medical attention immediately if ether is inhaled or
causes eye irritation. Failure to follow this warning may
cause death or serious injury to personnel.
48 Weekly Ether
Cold
Start Sys-
tem
Check for loose connections and
damage to lines, fittings, and
ether canister. Be alert for odor
of leaking ether.
Damage or evidence of leaks.
49 Monthly ROPS
and
FOPS
Check cab Roll Over Protective
Structure (ROPS) Falling Object
Protective Structure (FOPS) and
forklift frame for loose or miss-
ing mounting hardware and
obvious damage such as cracks
or bends.
Loose or missing mounting hard-
ware. Cracks or bends are evi-
dent.