TM 10-3930-660-10
0012 00-13
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
41 After Fuel/
Water
Separator
Remove drain plug on fuel/water
separator and drain water into a
container (WP 0019 00). Install
drain plug.
42 After Hydrau-
lic Oil
Reservoir
Check level of oil in hydraulic
oil reservoir. Oil level should be
visible in upper sight glass.
409-3008
DRAIN PLUG
FUEL/WATER
SEPARATOR
RIGHT SIDE OF ENGINE COMPARTMENT
409-019
UPPER
SIGHT
GLASS
HYDRAULIC
OIL TANK