PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
REAR
AND
RIGHT
SIDE
38 After Engine Check engine for any of the fol-
lowing conditions:
a. Fluid leaks such as oil, coolant
or fuel.
Class III oil, coolant or fuel leaks
are evident.
b. Loose, damaged or missing
drive belts.
c. Damaged coolant hoses.
d. Damaged electrical harnesses.
39 After Engine
Oil Level
Open compartment access door
and check level of oil on dip-
stick. Maintain oil level between
“ADD” and “FULL” marks.
40 After Trans-
mission
Oil Level
With engine running, transmis-
sion selector lever in N (Neutral)
and parking brake applied, check
level of oil on dipstick. Maintain
oil level between “ADD” and
“FULL” marks.
409-3007
OIL FILL
(OE/HDO)
DIPSTICK